IEC 60870‑5‑104

E41486

IEC 60870‑5‑104 is an international standard defining networked telecontrol communication protocols for supervisory control and data acquisition (SCADA) systems over TCP/IP in electrical power systems.

All labels observed (5)

Label Occurrences
IEC 60870-5-104 3
IEC 60870‑5‑104 canonical 3
IEC 104 1

How this entity was disambiguated

Statements (47)

Predicate Object
instanceOf SCADA communication protocol
international standard
telecontrol communication protocol
alsoKnownAs IEC 104
linked to: IEC 60870‑5‑104
applicationLayer IEC 60870‑5 application functions
linked to: IEC 60870‑5‑104
appliesTo electrical power systems
supervisory control and data acquisition systems
basedOn IEC 60870‑5‑101
category power system communication standard
telecontrol standard
communicationModel client‑server
competesWith DNP3 over TCP/IP
linked to: DNP3

IEC 61850 MMS
linked to: IEC 61850
defines networked telecontrol communication protocols
domain industrial automation
power system automation
ensures interoperability between SCADA devices
extends IEC 60870‑5‑101 to TCP/IP networks
focusesOn telecontrol for power system operation
layerModel uses TCP/IP as lower layers
networkLayer IP
partOf IEC 60870‑5 series
linked to: IEC 60870‑5‑104
publishedBy International Electrotechnical Commission
shortName IEC 60870‑5‑104
specifies application protocol data units
frame formats
link management procedures
time synchronization mechanisms
supports command transmission
cyclic data transmission
event reporting
file transfer functions
spontaneous data transmission
time‑tagged measurements
targetDevice SCADA master stations
linked to: DNP3

bay control units
protection relays
remote terminal units
transportLayer TCP
typicalUseCase communication between control center and bay controllers
communication between control center and substation RTUs
usedFor remote control of substations
remote monitoring of power system equipment
telecontrol in energy management systems
usedIn Asia
Europe
South America

How these facts were elicited

Referenced by (9)

Full triples — surface form annotated when it differs from this entity's canonical label.

IEC 61850 relatedStandard IEC 60870‑5‑104
IEC 60870‑5‑104 partOf IEC 60870‑5 series
linked to: IEC 60870‑5‑104
IEC 60870‑5‑104 shortName IEC 60870‑5‑104
IEC 60870‑5‑104 alsoKnownAs IEC 104
linked to: IEC 60870‑5‑104
IEC 60870‑5‑104 applicationLayer IEC 60870‑5 application functions
linked to: IEC 60870‑5‑104
DNP3 competesWith IEC 60870-5-104
linked to: IEC 60870‑5‑104
Distributed Network Protocol competesWith IEC 60870-5-104
linked to: IEC 60870‑5‑104
IEC 60870‑5‑101 relatedTo IEC 60870‑5‑104
SCADA systems commonlyUsesProtocol IEC 60870-5-104
linked to: IEC 60870‑5‑104