NRX reactor accident of 1952

E290831

The NRX reactor accident of 1952 was a major nuclear reactor incident in Canada involving a partial meltdown and significant radioactive release, making it one of the earliest serious accidents in nuclear power history.

All labels observed (2)

How this entity was disambiguated

Statements (48)

Predicate Object
instanceOf industrial accident
nuclear reactor accident
radiological incident
alsoKnownAs 1952 NRX reactor accident
NRX accident
cause inadequate communication of control rod status
malfunctioning control rods
operator error
cleanupOperation involved extensive decontamination of reactor building
involved removal of damaged fuel and reactor components
cleanupWorkers included Canadian military personnel
included civilian scientists and technicians
containmentMeasures pumping contaminated water to storage and disposal areas
venting of radioactive gases through stack
continent North America
country Canada
date 1952-12-12
environmentalImpact release of radioactive water into nearby environment after treatment and dilution
followedBy further safety upgrades at Chalk River reactors
healthEffects no immediate fatalities reported
workers received elevated radiation doses during cleanup
historicalSignificance highlighted importance of clear control room communication
influenced development of reactor safety procedures
one of the earliest serious accidents in nuclear reactor history
impactOnReactor NRX reactor was heavily damaged
linked to: NRX reactor

NRX reactor was later repaired and returned to service
linked to: NRX reactor
lessonsLearned need for better control rod interlocks
need for improved operator training
need for more robust emergency procedures
location Chalk River Laboratories
operator Atomic Energy of Canada Limited
precededBy early experimental reactor operations at Chalk River
radioactiveRelease contamination of reactor building and surrounding area
significant release of radioactive material into the reactor building
reactorCoolant light water
reactorInvolved NRX research reactor
reactorModerator heavy water
reactorType research reactor
regulatoryImpact contributed to improvements in Canadian nuclear safety regulations
relatedTo nuclear safety
reactor control systems
sequenceOfEvents control rods were withdrawn further than intended
fuel elements overheated and were damaged
reactor power increased uncontrollably
site Chalk River, Ontario
linked to: Chalk River
typeOfDamage fuel element rupture
partial core meltdown
year 1952

How these facts were elicited

Referenced by (2)

Full triples — surface form annotated when it differs from this entity's canonical label.

Chalk River Laboratories significantEvent NRX reactor accident of 1952
NRX reactor accident of 1952 alsoKnownAs 1952 NRX reactor accident
linked to: NRX reactor accident of 1952