Mark I

E799459

Mark I is a General Electric-designed boiling water reactor containment system characterized by a compact, pressure-suppression torus configuration used in several nuclear power plants worldwide.

All labels observed (2)

Label Occurrences
Mark I containment 2
Mark I canonical 1

How this entity was disambiguated

Statements (47)

Predicate Object
instanceOf boiling water reactor containment system ⓘ
nuclear reactor containment design ⓘ
belongsToSeries GE BWR containment Mark series ⓘ
linked to: GE Mark I
contrastedWith Mark II containment ⓘ
Mark III containment ⓘ
large dry containment ⓘ
countryOfUse Japan ⓘ
United States ⓘ
several other countries ⓘ
designer General Electric ⓘ
developedBy General Electric Nuclear Energy ⓘ
linked to: General Electric
followedBy Mark II ⓘ
Mark III ⓘ
hasComponent drywell ⓘ
suppression pool ⓘ
torus-shaped suppression pool ⓘ
vent pipes from drywell to suppression pool ⓘ
wetwell ⓘ
hasConfiguration pressure-suppression containment ⓘ
hasCriticism limited margin for pressure buildup in severe accidents ⓘ
hasDesignElement reinforced concrete secondary containment structures ⓘ
steel primary containment structure ⓘ
hasDesignGoal provide pressure suppression capability ⓘ
reduce containment size and cost ⓘ
hasFeature compact containment volume ⓘ
pressure-suppression torus ⓘ
wetwell and drywell arrangement ⓘ
hasMitigationMeasure filtered vent systems ⓘ
hardened containment vent systems ⓘ
hasRegulatoryAttention true ⓘ
hasRiskConcern potential for hydrogen accumulation ⓘ
vulnerability to severe core damage events ⓘ
hasShape compact torus configuration ⓘ
introducedAs early generation BWR containment design ⓘ
manufacturer General Electric ⓘ
notableEventAssociation Fukushima Daiichi nuclear disaster ⓘ
precededBy early prototype BWR containments ⓘ
pressureSuppressionMethod steam condensation in suppression pool ⓘ
primaryFunction containment of radioactive materials in accident conditions ⓘ
pressure suppression during loss-of-coolant accidents ⓘ
reactorType boiling water reactor ⓘ
safetyEnhancement post-Fukushima backfit modifications in several plants ⓘ
safetyObjective limit release of fission products during accidents ⓘ
typicalApplication BWR units of small to medium electrical output ⓘ
usedIn boiling water reactor nuclear power plants ⓘ
commercial nuclear power plants ⓘ
usedWorldwide true ⓘ

How these facts were elicited

Referenced by (3)

Full triples — surface form annotated when it differs from this entity's canonical label.

Unit 3 (nuclear) → safetyContainmentType → Mark I containment ⓘ
linked to: Mark I
BWR-3 → primaryContainmentType → Mark I containment ⓘ
linked to: Mark I